Railway Cables | ||||||||||
|
Digicode 30KHz Indoor Signalling Cables
Application
The cables are designed for transmission of track circuit digicode signals up to 30 kHz in electrifi ed lines.
Standards
EN 50266-2-4 & IEC 60332-3(Fire performance)
EN 50268-2(Smoke density)
EN 50267-2-1(Halogen content)
EN 50267-2-2(Gases acidity)
EN 50265-2-1, IEC 60332-1, NFC 32070 Cat C2 compliant (for PVC sheathed cables)
Construction
Conductors: Solid Annealed copper, 1.4 mm nominal diameter (0.6 mm for the auxiliary pair).
Insulation: Polyethylene.
Cabling Element: Two insulated conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded to get the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene.
Moisture Barrier: Copolymer coated laminated aluminium tape.
Intermediate Sheath: LSZH fi re retardant compound. PE or PVC option can be offered upon request.
Mechanical Protection: Two helically applied steel tapes.
Outer Sheath: LSZH fi re retardant compound. PE or PVC option can be offered upon request.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 1.4 |
---|---|---|
Maximum DC Conductor Resistance | Ω/km | 12.1 |
Maximum Resistance Unbalance | % | 3 |
Minimum Insulation Resistance @500 V DC (1min) | MΩ.km | 5000 |
Dielectric Strength (DC voltage 1 min) | ||
Conductor to Conductor | V | 1000 |
Conductor to Screen | V | 3000 |
Minimum Spark Test On Outer Sheath (AC voltage) | V | 5000 |
Maximum Mutual Capacitance (Data pairs) | nF/km | 45 |
Nominal Mutual Capacitance (Auxiliary pair) | nF/km | 50 |
Maximum Capacitance Unbalance | ||
Pair to Pair | nF/500m | 400 |
Pair to Ground | nF/500m | 1500 |
Maximum Characteristic Pair Attenuation | ||
@2.1KHz | dB/km | 0.64 |
@4.1KHz | dB/km | 0.76 |
@9.5KHz | dB/km | 1.05 |
@20.7KHz | dB/km | 1.28 |
Minimum Near End Crosstalk Attenuation (NEXT) | ||
@4.1KHz | dB/km | 54 |
@20.7KHz | dB/km | 42 |
Minimum Far End Crosstalk Attenuation (FEXT) | ||
@4.1KHz | dB/km | 59 |
@20.7KHz | dB/km | 48 |
Minimum Unbalance Attenuation | dB | 40 |
Maximum Rated Voltage, between pair conductors | V rms | 220 |
Maximum Rated Current | A rms | 1 |
Mechanical and Thermal Properties
Minimum Bending Radius: 8×OD (static); 16×OD (dynamic)
Temperature Range: -40℃ to +60℃ (during operation);
-20℃ to +50℃ (during installation)
Dimensions And Weight
Cable Code | Number of Pairs |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
||
---|---|---|---|---|---|---|
Inner | Interm. | Outer | ||||
RS/DIG-2Y2Y(L)HBH-1P1.4 | 1* | 0.7 | 1.3 | 1.5 | 17.9 | 428 |
RS/DIG-2Y2Y(L)HBH-2P1.4 | 2* | 0.7 | 1.3 | 1.5 | 19.2 | 497 |
RS/DIG-2Y2Y(L)HBH-3P1.4 | 3 | 0.7 | 1.3 | 1.5 | 20.2 | 562 |